PVC resin roof tiles are widely used due to their lightweight and weather-resistant properties. Before installation, carefully inspect the appearance of the tiles to avoid using materials with damaged edges or cracked surfaces. Also, prepare installation tools and accessories such as special self-tapping screws.
During installation, the spacing between roof purlins should not exceed 60cm, and the surface should be flat and free of debris. A sloped or uneven base will cause uneven stress on the tiles.
When overlapping tiles, special screws with waterproof pads must be used, and the spacing between screws should be controlled within 30-40cm. Too sparse spacing can cause the tiles to loosen, while too close spacing can damage the tile structure.
When overlapping, pay attention to the following: horizontal overlap lengths should be ≥10cm, and vertical overlaps should be ≥5cm. Furthermore, PVC composite resin tiles expand and contract with heat, so during installation, allow 3-5mm expansion joints at the eaves and ridges to prevent warping caused by temperature fluctuations.
After installation, prompt inspection is required to check whether screws are secure and seals are consistent. After heavy rain, inspect the roof for leaks to ensure that the installation meets quality standards.